RC007 RECEIVER

Receiver for high capacity motors.

SAFETY NOTES

Keep away from children to avoid any possible damage to the receiver caused by their play.
If the supply cord is damaged, it must be replaced by the manufacturer, the service agent or similarly qualified electrician in order to avoid a danger.
The receiver is of high voltage. Keep it away from water.
The installation pole is fixed to the installation board. Please be careful during the installation.

TECHNICAL SPECIFICATIONS

Power: AC120V(60Hz)
Rated Load: ≤1600W
Lighting Output: ≤500W Fuse Rated Currency: 8A
The receiver will power off automatically after working for 3 minutes continuously.
The receiver can be controlled by 15 remotes at most.

WIRE CONNECTIONS

The wiring 230V/50Hz is taken as an example. For 120V/60Hz, please refer to the corresponding standard.

rc007-wires

TERMINAL INSTRUCTION

Receiver for high capacity motors.

1. Please refer to the above instructions for wiring.
2. If the tubular motor runs in opposite direction, exchange the brown and black wire.
NOTE: Tubular motor’s power is 1600W.
3. A light can be wired at the “LIGHT” terminal if required. The “RUN TIMER” switch controls the light’s running time.
NOTE: The light’s power should be under 500W.

Program Setting

Note: We take RE110 keyring remote as an example. For any other remotes produced by our company, please follow the same instructions. The following “short press” means more than 0.5s and “long press” means more than 3s. The interval between every pressing should be at least 1s. There maybe other signal interference to cause setting to fail. Please set again.

rc007-terminals

CODE LEARNING

NOTES: After code learning, you can use the remote to control the tubular motor through UP, STOP and DOWN button.

rc007-codes

COPY

After copy, the new remote can control the motor as well.

rc007-copy

CODE DELETING

Long press the learning button on the receiver, the buzzer will ring once, and then ring again twice 2s later, now release the button, the code is deleted. All remotes that have learned receiver’s code cannot control this receiver.

rc007-code-delete

DIL SWITCH FUNCTIONS

keyring-remote

DIL1
IMPULSE OPEN tubular motor runs upwards continuously
DEADMAN OPEN tubular motor runs upwards from point to point

DIL2
IMPULSE CLOSE tubular motor runs downwards continuously
DEADMAN CLOSE tubular motor runs downwards from point to point

DIL3
3min RUN TIMER the light will be off after working 3 minutes
INFINITE RUN TIMER the light works all the time

DIL4
OPEN FUNCTION wall switch connects to terminal 2 and 3, the motor will run upwards
OR wall switch connects to terminal 2 and 4, the motor will run downwards

GO FUNCTION wall switch connects to terminal 2 and 4, the motor will run upwards, downwards and stop running

OTHER AUXILIARY CONNECTIONS

rc007-aux-connectionsA
rc007-aux-connectionsB
rc007-aux-connectionsC

TROUBLESHOOTING

Transmit LED of the remote does not light up - check the battery in the remote.

No reaction after signal sent - check the power and wire connection. Check if the temperature is normal (-10° - +55°C)

The remote distance becomes shorter - change the battery or check if there is any interference.

Remote is ok but the signal cannot be sent - check the power and the program setting.